AMPROBE
AT-2004 Advanced Tracer
Find Breakers and Hidden Wires
|
$999**
|
* Trace live conductors buried up to 13 feet. | ||
* Trace and identify load-side equipment from the circuit breaker while energized. | ||
* Trace line-side wiring without power interruption on circuits from 9 to 600V AC or DC. | ||
* Trace open wires for over a mile. | ||
* Trace wire in conduit or, even the conduit itself. | ||
* Locate ground faults and shorts. | ||
* Identify individual wires in a bundle. | ||
* Fully fused protected and intrinsically safe. | ||
* Fully portable and easy to use. | ||
Tracer Package Contains These Major Components: | ||
R2000 Receiver:
This component has two detectors in its tip which are tuned to pick up
the electromagnetic signals ('short' mode) or electrostatic signals ('open'
mode) generated by the other components. The LED's and sensitivity settings
indicate the relative signal strength to allow easy detection of the signal
source.
Specifications: Detectors: Electromagnetic coil pickup for short mode. Electrostatic plate pickup for open mode. Sensitivity Selection: x1, x10, x100 coarse gain adjustment; 0-10 fine adjustment Short Mode Performance: Over 20' in air under test conditions. Open Mode Performance: Over 12' in air under test conditions. 60 Hz Rejection: 120dB Power Source: 9V alkaline battery Display: 10 LED's with chroma filter lens Case: Flame Retardant ABS 911 |
||
S2600 Load Signal Generator: When connected to an energized line, will draw a rapidly fluctuating current pulse from the source, causing the power line to emit an electromagnetic signal which is detected by the R2000 Receiver in the "short" mode. This device allows tracing of of line-side conductors without power interruption or interference. Accepts 9-600V AC or DC. | ||
T2200 Transmitter:
Injects a signal into an unenergized conductor. If the conductor is broken
(open), no current will flow, so the signal is present as a voltage pulse,
which is detected along the conductor's length by the R2000's electrostatic
detector ('open mode'). The signal will stop at the open.
Specifications: Operating Frequency: 32.768 Khz Duty cycle: Transmits 2 pulses with a duration of 0.0635 sec. each every 0.5 seconds. Signal Output: 9V Supply 24V Supply High Setting: 1A, 31V 3A, 105V Medium Setting: 1.8A, 13V 6A, 45V Low Setting: 3.0A, 6.5V 10A, 22V Fuse: Fast acting 2A @ 250V 3AG 1/4" x 1.5" Battery: 9V alkaline Case: Flame retardant ABS911 |
||
Cordset | ||
AD-1 adapter | ||
A2201 clamp & operating manual | ||
GUARANTEE:
One year factory replacement for defects in material and workmanship. |