AMPROBE
 
 


AT-2004 Advanced Tracer



 
 

Find Breakers and Hidden Wires


 

$999**
 
 
 

 

* Trace live conductors buried up to 13 feet.
 
* Trace and identify load-side equipment from the circuit breaker while energized.
 
* Trace line-side wiring without power interruption on circuits from 9 to 600V AC or DC.
 
* Trace open wires for over a mile.
 
* Trace wire in conduit or, even the conduit itself.
 
* Locate ground faults and shorts.
 
* Identify individual wires in a bundle.
 
* Fully fused protected and intrinsically safe.
 
* Fully portable and easy to use.
 
 
Tracer Package Contains These Major Components:
R2000 Receiver: This component has two detectors in its tip which are tuned to pick up the electromagnetic signals ('short' mode) or electrostatic signals ('open' mode) generated by the other components. The LED's and sensitivity settings indicate the relative signal strength to allow easy detection of the signal source. 
    Specifications:
      Detectors: Electromagnetic coil pickup for short mode.
                       Electrostatic plate pickup for open mode.
      Sensitivity Selection: x1, x10, x100 coarse gain adjustment;
                                         0-10 fine adjustment
      Short Mode Performance: Over 20' in air under test conditions.
      Open Mode Performance: Over 12' in air under test conditions.
      60 Hz Rejection: 120dB
      Power Source: 9V alkaline battery
      Display: 10 LED's with chroma filter lens
      Case: Flame Retardant ABS 911
S2600 Load Signal Generator: When connected to an energized line, will draw a rapidly fluctuating current pulse from the source, causing the power line to emit an electromagnetic signal which is detected by the R2000 Receiver in the "short" mode. This device allows tracing of of line-side conductors without power interruption or interference. Accepts 9-600V AC or DC.
T2200 Transmitter: Injects a signal into an unenergized conductor. If the conductor is broken (open), no current will flow, so the signal is present as a voltage pulse, which is detected along the conductor's length by the R2000's electrostatic detector ('open mode'). The signal will stop at the open.
    Specifications:
     Operating Frequency: 32.768 Khz
     Duty cycle: Transmits 2 pulses with a duration of 0.0635 sec. each every 0.5 seconds.
     Signal Output:       9V Supply    24V Supply
     High Setting:         1A, 31V         3A, 105V
     Medium Setting:   1.8A, 13V       6A,  45V
     Low Setting:         3.0A, 6.5V     10A, 22V
     Fuse: Fast acting 2A @ 250V 3AG 1/4" x 1.5" 
     Battery: 9V alkaline
     Case: Flame retardant ABS911
Cordset
AD-1 adapter
A2201 clamp & operating manual
GUARANTEE
One year factory replacement for defects in material and workmanship.

  • **- An Additional Priority Shipping/Handling Charge of $34.00/unit will be Added to your Order Price.